© Sealevel Systems, Inc.
- 10 -
SIO4-104.2+2 User Manual
Available for use with the SIO4-104.2+2 is the CA228, the CA110/CA143, and the CA222/TB10
combination cables. These cables terminate the SIO4-104.2+2 40-pin header to four DB9M
connectors. This termination provides the standard DB9 pin out for RS-232 (EIA/TIA574) in
RS-232 mode. The following table illustrates the DB9 pin out when using any of these optional
cables.
RS-232
Signal Name DB-9 Pin # Mode
GND Ground 5
TD Transmit Data 3 Output
RTS Request To Send 7 Output
DTR Data Terminal Ready 4 Output
RD Receive Data 2 Input
CTS Clear To Send 8 Input
DSR Data Set Ready 6 Input
DCD Data Carrier Detect 1 Input
RI Ring Indicator 9 Input
RS-422
Signal Name Pin # Mode
GND Ground 5
TX + Transmit Data Positive 4 Output
TX- Transmit Data Negative 3 Output
RX+ Receive Data Positive 1 Input
RX- Receive Data Negative 2 Input
RS-485
Signal Name Pin # Mode
GND Ground 5
DATA+ Receive Data Positive 1 I/O
DATA- Receive Data Negative 2 I/O