Sealevel Systems ULTRA COMM+422 Page 18
Specifications
Environmental Specifications
Specification Operating Storage
Temperature
Range
0º to 50º C
(32º to 122º F)
-20º to 70º C
(-4º to 158º F)
Humidity Range
10 to 90% R.H.
Non-Condensing
10 to 90% R.H.
Non-Condensing
Manufacturing
IPC 610-A Class-III standards are adhered to with a 0.1 visual A.Q.L. and
100% Functional Testing.
All Sealevel Systems Printed Circuit boards are built to U.L. 94V0 rating
and are 100% electrically tested. These printed circuit boards are solder
mask over bare copper or solder mask over tin nickel.
Power Consumption
Supply line
+5 VDC
3440 Rating
600 mA
3441 Rating
570 mA
Mean Time Between Failures (MTBF)
Greater than 150,000 hours. (Calculated)
Physical Dimensions
Board length 8.0 inches (20.32 cm)
Board Height including Goldfingers 4.2 inches (10.66 cm)
Board Height excluding Goldfingers 3.9 inches (9.91 cm)